Site icon Techplayon

Open Midhaul F1 Interface F1-C and F1-U

The F1 interface connects a gNB CU to a gNB DU. This interface is applicable to the CU-DU Split gNB architecture. The control plane of the F1 (F 1-C) allows signaling between the CU and DU, while the user plane of the F1 (F 1-U) allows the transfer of application data.

Following figure illustrates the CP and UP protocol stacks belonging to the F1 interface. The C-plane uses SCTP over IP, whereas the U-plane uses GTP-U over UDP over IP for transport layer.

F1 Interface Characteristics:

F1 Interface Functionalities

F1 Interface performs following management operations.

Control Plane Functionalities:

User Plane Functionality: